A 66 year-old female tripped and fell while getting out of a car. Her past surgical history included a left Total Knee Replacement (TKR) performed six months earlier. Radiographs revealed a left-sided comminuted periprosthetic femur fracture proximal to the femoral component. A CT Scan was performed and the femoral compenent was determined to be stable. Through a minimally invasive technique with indirect reduction, the fracture was reduced and fixed using a LISS locking plate and screws. She returned for regular follow-up and healed uneventfully and at 2 years she presents with an excellent outcome including a healed periprosthetic femur fracture, resolution of pain, and a return to pre-injury activities.
IMAGES
- Figure A Anteroposterior (AP), and lateral injury radiographs revealing a left-sided comminuted periprosthetic femur fracture.
|
- Figure B CT scan images and 3D CT reconstruction images further dilineating the fracture pattern.
|
- Figure C Preoperative plan for fracture reduction and fixation with a LISS locking plate.
|
- Figure D AP and lateral views at 2 years following fracture surgery illustrate a healed periprosthetic femur fracture.
|
 |